  data sheet zfk, zrm general measuring object: oxygen contained in noncombustible gas measuring principle: direct-insertion zirconia system measuring range: 0 to 2 50 vol% o 2 freely settable (in 0.5% steps) repeatability: within 0.5% of max. output signal linearity: 2% of full scale response time: within 7sec for 90% response (from calibration gas inlet) power supply: 100, 115, 220 or 230v ac, 50/60hz power consumption: (approx.) 15 + 50va (at steady state of general-use detector) 15 + 200va (at start of general-use detector) warmup time: approx. 15min oxygen detector (zfk2,5), ejector (zta) measuring detector: for general-use: zfk2 for corrosive gas: zfk5 converter this oxygen analyzer is used to continuously measure oxygen concentration in combustible exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion moni- toring and control. the detector (zfk) used with the analyzer is directly inserted into the objects measured, eliminating the need for a sampling device and provides quick response. the converter (zrm) features automatic calibration and blowdown functions. the adoption of liquid crystal display facilitates operation and setting in interactive mode. besides the general-use type detector, corrosion resisting type and high temperature type are available for selection according to applications. 1. output range easily set output range can be easily set in 0.5% increments within the scope of 2 to 50%. when oxygen decreases, in- complete combustion level appears on the display (rich mode; output voltage of oxygen detector), instead of oxygen concentration. 2. automatic calibration/blowdown function automatic calibration and manual/auto blowdown func- tions are provided as standard functions. an external solenoid valve is required. 3. easily operated in interactive mode interactive mode is adopted to the liquid crystal display for operation and parameter setting, facilitating use even for beginners. 4. combustion efficiency display function combustion efficiency calculated from oxygen concent- ration and temperature of exhaust gas can be displayed as an optional function, which is useful to improve combus- tion efficiency. 5. sampling device is unnecessary gas sampling devices such as a gas aspirator, a dehu- midifier, etc. are unnecessary because of use of direct- insertion type detector. the adoption of a flow guide tube utilizing the flow of the measured gas assures quick response (less than 7sec). 6. selection of detector type according to applications besides the general-use type detector used under temperatures of less than 600 c, a corrosion-proof de- tector for measuring incinerator exhaust gas, and a high temperature type detector using heat insulator for the ejector and insertion tube, capable of measuring temperatures up to 1590 c, are available for selection according to applications. general-use detector high-temperature detector in-situ zirconia oxygen analyzer < zircomat-p > features specifications date EDSX3-113C nov. 30, 2001
zfk, zrm 2 repeatability: 0.5% of full scale linearity: 1.0% of full scale indication: oxygen concentration; 3-digit led operation/setting display: 16-digit, 2-line lcd mode display: 3pcs led oxygen concentration output signal: 4 to 20ma dc (allowable load resistance: 500 ? or less) or 0 to 1v (output resistance: 100 ? or less) isolated output, linear contact output signal: (1) contact specification; 4 points, n.o. (1a), 250v ac, 2a (2) contact function; under maintenance under blowdown span calibrating gas zero calibration gas following functions freely selected high limit alarm low limit alarm high/low limit alarm fault (abnormal) contact input signal: auto. calibration start (auto. calibration starts when contact closes) calibration disable (calibration disabled when contact closes) contact specification; isolated, on at 1k ? or less calibration method: (a) manual calibration with key operation (b) auto. calibration (standard function) calibration cycle; 00 day 00 hour to 90 days 60 hours calibration gas: range settings zero gas; 0.010 to 50.000% o 2 span gas: 8.000 to 23.000% o 2 recommended calibration gas concen- tration zero gas; 0.25 to 2.0% o 2 span gas; 20.6 to 21.0% o 2 (oxygen concentration in the air) blowdown: a function for blowing out with com- pressed air dust that has deposited in the flow guide tube. blowdown can be performed for a predetermined time and at predetermined intervals. blowdown cycle; 00 hour 00 minute to 99 hours 60 minutes blowdown time; 0 minute 00 second to 9 minutes 60 seconds output signal hold: output signal is held during calibration and blowdown. the hold function can also be released. transmission function (option): rs-485 transmission distance; max. 500m total number of units connected; max. 8 units half-duplex bit serial transmission, start- stop synchronization. measured gas temperature: flow guide tube system; ?0 to +600 c (for general-use, corrosive gas) ejector system; ?0 to +1590 c (for high-temperature gas) ?0 to +800 c (for general-use) measured gas pressure: ? to +3kpa (?06 to +306mmh 2 o) flow guide tube: with or without blow-down nozzle flange; jis5k 65a ff (jis5k-80aff for high particulate gas) insertion length; 0.3, 0.5, 0.75, 1m (0.8m for high particulate gas) ejector (general-use): probe for guiding measured gas to de- tector flange; jis10k 65a rf insertion length; 0.5, 0.75, 1, 1.5m (according to customer's specification) ambient temperature: ?0 to +60 c for cable section ? to +100 c for ejector section 125 c or less at detector flange surface with power applied structure: dust/rain-proof structure(iec ip55 equivalent) filter: alumina(filtering accuracy 50 m) and quartz paper main materials of gas-contacting parts: general-use detector; zirconia, sus316, platinum anticorrosive detector; zirconia, tita- nium, platinum flow guide tube; sus304 or sus316 ejector (general use);sus316, sus304 ejector; (for high temperature) sic, sus316, sus304 calibration gas inlet: sus316 reference air inlet (option): rc1/8 or npt1/8 detector mounting: horizontal plane 45 , ambient sur- rounding air should be clean. outer dimensions: (l x max. dia.) 210mm x 100mm (detector) mass (approx.) {weight}: detector; 1.6kg ejector; 15kg (insertion length 1m) flow guide tube (general-use, 1m); 5kg finish color: silver and sus metallic color ejector air inlet flow rate: 5 to 10 r /min blowdown air inlet pressure: 200 to 300kpa {2 to 3 kgf/cm 2 } ejector exhaust gas processing: within furnace, returned to flue heater temperature drop alarm output (ejector): alarm output when below 100 c mechanical thermostat n.o. (1a) contact, 200v ac, 2a oxygen converter (zrm) measuring range: 0 to 2 50 vol% o 2 freely settable (in 0.5% o 2 steps)
3 remark: w hen connecting via an rs- 232c interface, a rs232 ? rs 485 converter should be used. combustion efficiency display (option): this function calculates and displays combustion efficiency from oxygen concentration and measured gas temper- ature. thermocouple (k or r) is required for temperature measurement. rich mode display: when the detector output voltage ex- ceeds 200mv (0.0023%o 2 ), the rich mode (fuel rich) is indicated in lcd where the led showing the detector output voltage flickers. self-diagnosis function: provided for detector temperature fault, zero calibration fault, span calibration fault, calibration disable, and detector output fault. ambient temperature: ?0 to +50 c ambient humidity: 90% rh or less power supply: 90 to 220 or 230 v ac, 50/60hz construction: dust-proof, rainproof construction (corresponding to ip53 of iec) material: steel outer dimensions (h x w x d): 220 x 193 x 89mm mass {weight}: approx. 3.5kg (excluding cable and de- tector) finish color: munsell 2.5y8.4/1.2 mounting method: mounted flush on panel or on pipe the product conforms to the requirements of the electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tz734575. the applicable standards used to demonstrate compliance are : en 55011 : 1992 classa conducted and radiated emissions en 50082-1 : 1992 radiated immunity, esd and fbt zfk, zrm electrical safety: overvoltage category ; ii power supply input ; i relay interfaces (iec1010-1) external overcurrent protective device ; 10a equipment interfaces are safety separated (selv)
zfk, zrm 4 (converter) (exclusive-special cable) note: for connection between detector and converter, the conduit to be used should be rainproof flexible type. (ejector) (detector) ( replacement detector element) note: specify the detector type. (zfk 2 or 5, r-type or k-type thermo- couple) code symbols 1 1 a t z 2 1 345678 description measured gas temperature for high temperatures (+1590 c max.) general-use (+800 c max.) insertion length [mm] 500 750 1000 1500 power supply 100v/115v ac 50/60hz 200v/220v ac 50/60hz 230vac 50/60hz 1 2 b c d e 1 3 5 - 1 m z r z 9 2 1 345678 description connectable devices for zrm conduit length cable length none 6m none 10m none 15m none 20m none 30m none 40m none 50m none 60m none 70m none 80m none 90m none 100m 6m 6m 10m 10m 15m 15m 20m 20m cable end treatment none one side (detector side) both sides types for r thermocouple m r ya yb yc yd ye yf yg yh yj yk yl ym aa bb cc dd 0 1 2 - 1 1 m r z1 9 2 1 345678 description output signal 4 to 20ma dc 0 to 1v dc optional functions none serial communication (rs-485) combustion efficiency display transmission function + combustion efficiency display power supply 90 to 220v ac 50/60hz 230vac 50/60hz (ce marking approved) b e y a b c 1 5 mounting method panel mounting pipe mounting 1 2 4 zfk 14 9 10111213 45678 description flow guide tube flange application length none sus304 general use 300mm sus304 general use 500mm sus304 general use 750mm sus304 general use 1000mm sus316 for corrosive gas 300mm sus316 for corrosive gas 500mm sus316 for corrosive gas 750mm sus316 for corrosive gas 1000mm sus316 with blow-down nozzle 300mm sus316 with blow-down nozzle 500mm sus316 with blow-down nozzle 750mm sus316 with blow-down nozzle 1000mm sus316 for high particulate 300mm sus316 for high particulate 500mm sus316 for high particulate 750mm sus316 for high particulate 1000mm sus316 for high particulate with 300mm cover sus316 for high particulate with 500mm cover sus316 for high particulate with 750mm cover sus316 for high particulate with 1000mm cover others protection cover without with power supply 100/115vac 50/60hz 200/220vac 50/60hz 230vac 50/60hz (ce-marking approved) cal. gas inlet for 6mm tube for 1/4 inch tube kinds standard 0 y 0 5 a 3 5 a 5 5 a 7 5 a 1 5 b 3 5 b 5 5 b 7 5 b 1 5 c 3 5 c 5 5 c 7 5 c 1 6 d 3 6 d 5 6 d 7 6 d 1 6 e 3 6 e 5 6 e 7 6 e 1 z z z y a b z r application general use for corrosive gas (refuse incinerator) 2 5 y a 1 3 5 1 2 non-standard spec. other non-standard items reference air inlet non rc1/8 npt1/8 4y y y 00 zfk 9 10111213 45678 description power supply 100/115vac 50/60hz 200/220vac 50/60hz 230vac 50/60hz cal. gas inlet polypropylene joint for 6 tube brass joint for 1/4 inch tube kinds standard r application general use (tc516041) for corrosive gas (refer to incinerator) (tc516042) 2 5 1 3 5 6 7
5 converter (zrm) flow guide tube system rc1/4 (upper side blow port should be selected) blow-down, 200 to 300kpa {2 to 3kgf/cm 2 } solenoid valve (not supplied) reduction valve (unnecessary when supply air pressure is 200 to 300kpa {2 to 3kgf/cm 2 } 15asgp tube equivalent (not supplied) 15asgp tube equivalent (not supplied) or 10/ 8 ptfe pipe or copper pipe rainproof cover detector zfk2 zfk5 flow guide tube gas temperature. 600 c max. gas temperature. 600 c max. gas temperature. 600 c max. sample gas outlet sample gas outlet flow guide tube for high particulate flow guide for high particulate with cover 6mm or 4 inch tube for calibration gas (not supplied) rainproof flexible conduit. 20m max. 1 2 3 4 5 6 bule yellow white white black 4-core cable 2-core cable ac power supply analog output auxiliary input zirconia signal thermocouple signal maintenance contact blow-down contact heater 1 2 3 4 5 6 7 8 9 10 11 12 13 14 serial communication contact input calibrating gas contact ac power supply 15 16 17 18 19 20 21 22 23 24 25 26 27 28 4 to 20ma dc (0 to 1v) blue yellow red white black white cell/thermocouple output heater power supply pe solenoid valve (not supplied) solenoid valve (not supplied) reduction vale (zbd6) reduction valve (zbd6) *1 air supply *1 standard gas for span point (zbm) reduction valve (unnecessary when supply air pressure is 50 to 100kpa {0.5 to 1kgf/cm 2 } standrad gas for zero point (zbm) joint flowmeter (zbd4) (1 to 1.5 r /min) (0.2 to 0.5 r /min) to detector *1 sandard gas or instrumentation air can be used in plase of span gas. *2 instrument quality air or bottled air is available as reference air instead of ambient air. *2 ref. air ac power supply ac power supply nc sg fg n l rs-485 supply air red note configuration
zfk, zrm 6 1 2 3 4 5 6 standrad gas for zero point (zbm) nc sg fg n l rs-485 gas temperature. 1590 c max. ejector (zta) ejector (5 to 10 r /min) reduction valve (unnecessary when supply air pressure is 200 to 300kpa {2 to 3kgf/cm 2 } ) 6/ 4mm copper pipe 10/ 8mm copper pipe 10/ 6mm copper pipe flowmeter (zbd) ref. air (0.2 to 0.5 r /min) rainproof flexible conduit. 2-core cable 4-core cable detector (zfk2) serial communication contact input calibrating gas contact ac power supply 15 16 17 18 19 20 21 22 23 24 25 26 27 28 solenoid valve (not supplied) solenoid valve (not supplied) reduction vale (zbd6) reduction vale (zbd6) *1 air supply *1 standard gas for span point (zbm) reduction valve (unnecessary when supply air pressure is 50 to 100kpa {0.5 to 1kgf/cm 2 } joint flowmeter (zbd4) to detector *1 standard gas or instrumentation air can be used in place of span gas. *2 instrument quality air or bottled air is available as reference air instead of ambient air. ac power supply ac power supply 4 to 20ma dc (0 to 1v) blue yellow red white black white cell / thermocouple output heater power supply ejector system 1 2 4 5 power supply heater temperature drop alarm joint supply air *2 solenoid valve (not supplied) bule yellow white white black red (1 to 1.5 r /min) note: converter (zrm) ac power supply analog output auxiliary input zirconia signal thermocouple signal maintenance contact blow-down contact heater 1 2 3 4 5 6 7 8 9 10 11 12 13 14 pe 6mm or 4 inch tube for calibration gas (not supplied)
7 detector: detector main unit x 1, viton o ring x 2, mounting screw (m5mm x 16) x 6, thermal sticker x 1, flow guide tube (as specified) x 1, ceramic filter x 1, rainproof cover (as specified) x 1 converter: converter main unit x 1, mounting bracket set, (according to specification) x 1 accessories (ac250v 500ma t fuse x 2, ac250v 3.15a t fuse x 2) ejector: ejector main unit x 1, insertion tube x 1, m16mm nut, and washer x 4, packing x 1 items to be prepared separately: (1) standard gas for calibration type zbm nsh4-01 (up to 5% o 2 range) type zbm nsj4-01 (over 5% o 2 range) (2) reduction valve for standard gas (type zbd61003) (3) flowmeter type; zbd42203, 0.2 to 2 r /min (for calibrating gas) type; zbd42403, 1 to 10 r /min (for ejector) the device to be combined differ according to the conditions of the gas to be measured. select the devices to be combined with reference to the following table. cautions if combustible gas (co, h 2 etc.) exists in the measured gas, error will occur due to burning at the sensor section. the inclusion of corrosive gas (si vapor, alkaline metal, p, pb etc.) will shorten the life of the sensor. when the measured gas temperature is high (+300 c or higher), the flange should be separated from the furnace wall in order to bring the detector flange surface temperature below the specified value +125 c). the flow guide should be attached in the direction in which the gas flow to the detector decreases. when much dust is included in the gas, the flow guide tube should be attached at an inclination so that the flow goes from below to above. and the flow guide should be attached in the direction in which the gas flow to the detector decreases. in the case of a refuse incinerator, automatic blow down of the flow guide should not be performed (to prevent corrosion of the flow guide tube due to drainage). blow- down should be performed manually when change in the indication has become very little with the furnace stopped. dust less than 0.2g/mm 3 less than 10g/nm 3 less than 1g/nm 3 less than 10g/nm 3 less than 25g/nm 3 less than 25g/nm 3 less than 1g/nm 3 less than 1g/nm 3 ejector type zta2 zta1 protection cover no yes note fuel; gas, oil fuel: coal with blow down included low moisture included low moisture with blow down included low moisture with blow down included high moisture with blow down sus316 tube with blow down sic tube with blow down temperature 600 c or less 600 c or less 800 c or less 1590 c or less gas flow 5 to 20m/s 5 to 20m/s less than 1m/s less than 1m/s measured gas device configuration note (1) dust volume is approximate value. (2) instrument quality air or bottled air is available as reference air by selecting detector with reference air inlet. detector type zfk2r 4- a zfk2r 4- c zfk5r 4- b zfk5r 4- c zfk5r 4- d zfk5r 4- e zfk2r 4-oyo zfk2r 4-oyo application general-use (boiler) for corrosive gas (refuse incinerator) general-use (boiler) converter type zrm zrm zrm zrm zrm zrm zrm zrm 5 5 5 5 6 6 scope of delivery device configuration
zfk, zrm 8 approx. 130 approx. 65 approx. 25 approx. 118 5 proof cover (to order) filter calibration gas inlet (to order) sus316 for 6/ 4 ptef tube or 1/4 inch tube. exclusive cable gland a 85 6- 6 ref. air inlet (to order) npt1/8 or rc1/8 60 36 26 45.4 80 67 black / white/ red / white/ yellow / blue 1 2 3 45 6 heater thermocouple element output 2-core wire 4-core wire exclusive-special cable external connection diagram detector (zfk2) flow guide tube 12 approx. l approx. 20 34 oxygen detector gas outlet gas inlet 8?5 mtg. holes 20 6-m5 detector side 67 130 155 3 l (m) mass 57 1 0.3 0.5 0.75 1.0 2.7 3.3 4.1 4.8 l= (to order) z approx.(kg) cord 11th z f k 2 r 4 - 5 a 3 5 7 1 5 7 1 18 approx. l approx. 20 67 60.5 gas inlet 8 15 mtg. holes 6-m5 detector side 67 130 155 z f k 2 r 4 - 5 c 3 3 l (m) 57 1 3.0 3.8 4.8 5.7 l= (to order) z approx.(kg) cord 11th flow guide tube (with blow-down nozzle) gas outlet oxygen detector 3 0.3 0.5 0.75 1.0 4-rc1/4 with plug int.thd. blow down air inlet select an upper port to avoid the condensation in the piping mass outline diagram (unit:mm)
9 8 - 19 mtg. hole blow down air inlet select an upper port to avoid the condensation in the piping 67 29.5 145 180 4 - rc 1/4 with plug int thd. flange: jis 5k80a ff zfk mtg. position 50 30 185 800 gas flow gas outlet packing flow guide tube (for high particulate) tube (50a sch40) 3 5 7 1 z f k 2 r 4 - 6 d 3 l (m) 57 1 4.5 5.6 7.0 8.3 l= (to order) z approx.(kg) cord 11th 0.3 0.5 0.75 1.0 mass 8 - 19 mtg. holes blow down air inlet select an upper port to avoid the condensation in the piping 67 29.5 145 180 4 - rc 1/4 with plug int thd. flange: jis 5k80a ff zfk mtg. position 50 30 (175) 800 (790) gas flow gas outlet packing (38) protection tube (65a sch40) tube (50a sch40) flow guide tube (for high particulate with cover) 3 5 7 1 z f k 2 r 4 - 6 e 3 l (m) 57 1 7.1 9.0 11.4 13.6 l= (to order) z approx.(kg) cord 11th 0.3 0.5 0.75 1.0 mass
zfk, zrm 10 approx. 35 approx. 118 approx. 130 approx. 65 5 proof cover (to order) filter calibration gas inlet (to order) sus316 for 6/ 4 ptef tube or 1/4 inch tube. exclusive cable gland 6- 6 ref. air inlet (to order) npt1/8 or rc1/8 60 black / white/ red / white/ yellow / blue 1 2 3 45 6 heater thermocouple element output 2-core wire 4-core wire exclusive-special cable external connection diagram detector (zfk5) 26 36 45.4 67 80 flow guide tube 12 3 approx. l approx. 40 60.5 oxygen detector gas outlet gas inlet 8- 15 mtg. holes 67 130 155 3 l (m) mass 57 1 0.3 0.5 0.75 1.0 3.3 4.5 6.1 7.6 l= (to order) z approx.(kg) cord 11th z f k 5 r 4 - 5 b 3 5 7 1 67 6-m5 detector side flow guide tube (with blow - down nozzle) 18 3 approx. l approx. 20 60.5 oxygen detector gas outlet gas inlet 8- 15 mtg. holes 67 130 155 3 l (m) mass 57 1 0.3 0.5 0.75 1.0 3.3 4.2 5.7 7.4 l= (to order) z approx.(kg) cord 11th z f k 5 r 4 - 5 c 3 5 7 1 67 6-m5 detector side 4- rc 1/4 with plug int. thd. blow down air inlet select an upper port to avoid the condensation in the piping
11 8 - 19 mtg. hole blow down air inlet select an upper port to avoid the condensation in the piping 67 29.5 145 180 4 - rc 1/4 with plug int thd. flange: jis 5k80a ff zfk mtg. position 50 30 185 800 gas flow gas outlet packing flow guide tube (for high particulate) tube (50a sch40) 3 l (m) mass 57 1 0.3 0.5 0.75 1.0 4.5 5.6 7.0 8.3 l= (to order) z approx.(kg) cord 11th z f k 5 r 4 - 6 d 3 5 7 1 8 - 19 mtg. holes blow down air inlet select an upper port to avoid the condensation in the piping 67 29.5 145 180 4 - rc 1/4 with plug int thd. flange: jis 5k80a ff zfk mtg. position 50 30 (175) (800) 790 gas flow gas outlet packing (38) protection tube (65a sch40) tube (50a sch40) flow guide tube (for high particulate with cover) 3 l (m) mass 57 1 0.3 0.5 0.75 1.0 7.1 9.0 11.4 13.6 l= (to order) z approx.(kg) cord 11th z f k 5 r 4 - 6 e 3 5 7 1
zfk, zrm 1234567891011121314 15 16 17 18 19 20 21 22 23 24 25 26 27 28 a.out aux.in output signal auxiliary input zr.sig element input t.c ment blow heat thermo- couple maintenance contact blow contact heater power supply dxa dxb g d11 d12 di com zv com sv serial communication power supply pe n l contact input calibrating gas contact sg fg power wiring port, 3- 23. with rubber bushing note (1) : the numbers 1 through 6 denote detector terminal no. for exclusive - special cables. 6 5 3 4 1 2 4-core cable 2-core cable external connection diagram converter (zrm) panel flush mounting pipe mounting ( 2 ) : m3 terminal screws are used for the terminal block. 204 193 6 50 220 200 194 55 28 37 176 9 35 cable gland 18 88.6 2b pipe for mounting ( 60.5 0.5mm) p ac power supply heater temp.drop alam ejector air inlet (rc1/4) ejector air outlet (rc1/4) cable gland (a15c) blow -down air inlet (rc1/4) detector (zfk2) external connection daiagram (jis 10k65arf) 140 8 105 25 viewed from p direction gas inlet approx. l 190 217 42.7 30 170 40 40 50 45 4-m16 bolt ejector (zta) 35 l [mm] 500 750 1000 1500 1 2 3 4 5 information in this catalog is subject to change without notice. printed in japan head office 6-17, sanbancho, chiyoda-ku, tokyo 102-0075, japan http://www.fesys.co.jp/eng sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http: //www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDSX3-113C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X